Corrigo ventilation user guide, revision F Corrigo ventilation user guide, revision FFel! Page 5 Change-over is a function that enables using the same pipe for both heating and cooling, depending on which is currently required. Page 6 The value can be changed by the parameter pressing OK.

Author:Tulabar Vudokasa
Country:Cyprus
Language:English (Spanish)
Genre:Finance
Published (Last):20 September 2005
Pages:256
PDF File Size:20.68 Mb
ePub File Size:8.7 Mb
ISBN:249-5-76229-672-4
Downloads:96159
Price:Free* [*Free Regsitration Required]
Uploader:Meztishura



The controllers have a display and built in panels for operation and alarm on the front and are operated by means of clearly defined buttons. Page 3: Model Overview U10 - U20 Overview - models for heating control for heating control is available in two models which differ slightly in their ORRIGO control function and in the number of inputs and outputs. The function of some of the inputs varies depending on the choice of model and configuration.

AI-inputs must always use the signal neutral of the AI terminal block as reference. These inputs may only be wired to voltage-free contacts. Important These inputs may only refer to the common DI pole on terminal DO6 ut The outputs DO DO6 are triac controlled, 0.

Short term 1 A. Page 12 Buttons on the front Arrow up — move upwards in the menu. When the button is held in a depressed position the function is repeated. Arrow down — move downwards in the menu. Page Alarm Handling - Alarm Queue Menu information If the user attempts to make changes that cannot be made or which lie outside his user level the controller will display the following information: Unauthorised No changes in Make new logon this menu Menu help text There are extra help-text to most of the menu pages.

Page 15 3. Should the code for level three be lost the sys- tem can be opened by means of a code number which can be obtained from REGIN. This code number is time dependent. Manual C Configuration codes There is also the option of setting parameters by means of two configuration codes.

This function is particularly useful and time-saving when a number of controllers are to be configured in the same way. Page 17 Configuration Some of the functions are not available on all models. This due to that some of the inputs or outputs have alternative functions. Function sensor AI1 Outdoor sensor. Fixed setting. Do not change Since the heating control is outdoor temperature dependant this sensor must be installed and configured for correct function.

Page 18 G. Function as for AI2, see point B. Page 19 O. Page Control Hs1 Konfigurering, snabbmetod At the top of the configuration branch there are two menues, Configuration code 1 and Configuration code 2.

Each position in the code corresponds, in order, to hte menues A to V described on the previous pages. The codes may be set directly in these two menues. Tables for configuration code There is also a special table to facilitate the choice of configuration code.

Page Outputs AO Analogue out In this menu branch you can look at the configuration and output of the analogue outputs. Only shown if HS1-CV1-type is configured as Page Scheduler Scheduler The C has a year-base clock. The clock has at least 24 hours running reserve. Clock Can be changed from userlevel 1 and up. Time In this menu you can set date and time. Page Alarm Settings And Alarm Queue Alarm settings Here all settings for the alarm system are set including alarm parameters, delays, suppression times etc.

Temperature deviation alarm HS1 Temp. Page Settings other Settings This menu contains various settings that are normally only set at the comissioning of the C ORRIGO Which alternatives are shown depends on the model and the configuration settings.

K-factor HS1-Room Sets the ratio between a change in supply water temperature and the resulting change in room temperature.

U V Configuration code 2 0 0 0 0. M Not available to Corrigo U10 0. Yes N Room compensation HS2 0. Our products are designed for creating a pleasant indoor climate while, at the same time, utilizing energy in the most cost-effective way possible. This manual is also suitable for:.

ANDAL THIRUPPAVAI LYRICS IN PDF

Контроллеры Corrigo E

The controllers have a display and built in panels for operation and alarm on the front and are operated by means of clearly defined buttons. Page 3: Model Overview U10 - U20 Overview - models for heating control for heating control is available in two models which differ slightly in their ORRIGO control function and in the number of inputs and outputs. The function of some of the inputs varies depending on the choice of model and configuration. AI-inputs must always use the signal neutral of the AI terminal block as reference.

10 SCROLLS OG MANDINO PDF

Regin Corrigo U10 Series User Manual

Оттаивание пластинчатого теплообменника. Сигнализация аварий Контроллер имеет входы для сигналов неисправности, которые поступают с выходов: вентилятора, насоса, датчика защиты от замерзания, датчика защиты ТЭНа, компрессора DX-охладителя, дымового детектора, обмерзания теплообменника, внешней аварии. При аварии на дисплее отображается: время аварии и расшифровка аварии. При этом загорается красный светодиод. Все аварии требуют ручного подтверждения. Уровни доступа Система меню разделена на четыре пользовательских уровня, что сводит к минимуму опасность неверного задания параметров. Просматривать значения параметров и подтверждать аварийные сигналы можно и не входя в систему.

BILL GLAZER OUTRAGEOUS ADVERTISING PDF

Контроллер REGIN Corrigo L10

Регуляторы температуры Regin. Читать далее. Дисплейный блок DSP 2. Инструкция пользователя. Дисплей, индикаторы и кнопки. Максимальное отклонение от уставки при регулировании:

ANTON BRUCKNER LOCUS ISTE PDF

Regin CORRIGO L10 Manuals

It has been designed for use in less complex air-handling systems. The controller has a display and built in indicator on the front for alarm and is operated by means of clearly defined buttons. DI3 Ext. Exception: The AI4 input is used as a digital input when the unit is configured with overheat protection on an electric heater. In that case, connect this input to a poten- tial free closing contact.